- 3,615 lbs/hr @ 175PSI @ 650 degrees F, steam Abco, natural gas fired, thermal oxidizer. Serial #9336, National Board #3169, built 1993. 562 square feet heating surface.Castable refractory oxidizer. View Photo! - Click here to request more information
- 21.0MM BTUH Trane Thermal chlorinated hydrocarbon incinerator w/waste heat recovery. Designed for various chemical solvents entrapped w/water. Max flow of water for incineration 1550 lb/hr. Unit is rated @ 21MM BTUH system consists of Trane Thermal horiz incinerator 6'6" dia x 15' long. Refractory lined. CS shell. Primarily fired on steam atomized #6 fuel oil. Maintaining a min temp of 2400 deg F. Burner is Trane Thermal LV-24 vortex burner. Firing 140 gph max, gas pilot ignition. Auxillary equipment for burner includes FM insurance approved piping train for #6 fuel oil and waste. Waste piping is 316SS. Main combustion air fan is CS Spencer turbine rated 5,000 scfm @ 24 osig, powered by UL label 60 HP, 3/60/460 volt motor. ABCO elevated drum fire tube waste heat boiler. Single pass, 5'10" dia x 30' long x 13' high. Producing 10,000 lbs/hr @ 200 psig saturated steam. Feed water rate 250 psig-7650 lb/hr @ 220 deg F. Scrubber system is packed column 3'6" dia x 18'. CS shell lined w/Pyroflex and 4 1/2" acid brick. Ceramic intalux saddle packing. Stack is 12" dia x 10' high FRP. Quench air fan requires 30 HP motor (motor is missing). CS Garden City, designed temp 700 deg F. Pumps for scrubber system are duplexed 316SS Durco 5 HP, 3490 rpm. Remote control panel controls and meters. Boiler inlet temp, waste solvent feed rate, steam produced, scrubber exit temp, recycle air temp, incinerator chamber temp, boiler water level, feed water rate to boiler, liquid level in scrubber. View Photo! - Click here to request more information
- Approx 835 cfm Trane Thermal fume incinerator. Mfd by Trane Thermal Co. System designed to incinerate combustible chemical fumes for air pollution compliance. Operated on DMA plant Emissions w/max content of 127 lb/hr Dimethyl ether, 9 lb/hr methanol and 27 lb/hr DMA dimethylaniline, incinerating "all organics in vent gases". Oil fired w/gas pilot. Unit skid mtd. Prepiped and prewired. Click here to request more information
- 8,500 cfm vert brick lined CS fume incinerator. Mfd by Air Preheater. Main oxidation chamber measures 5' wide x 32' long x 14' high. CS construction w/refractory lining. Dual fuel gas and #6 oil. W/controls and burner. Click here to request more information
- 3,000 scfm induced draft horiz vapor incinerator. Mfd by Hirt Combustion Engr, Mdl HIH-5M3000X, SN 8601270. W/automatic inlet damper. Unit designed to incinerate 3,000 scfm @ 1200 deg F using natural gas. Inlet fumes were 300 deg F. Induced draft fan operated @ 500 deg F w/13,312 cfm flow rate. View Photo! - Click here to request more information
|