- 21,660 HP GHH Sterkrade hot gas expander. Model GTHR7/130. 130 psi inlet @ 1150 degree F, exhaust 15 psi. Flow 347,642 lbs/hr. Maximum operating temperature 1318 degree F. Maximum cont speed 6020 rpm, trip setting 6622 rpm, 5733 rpm. 1-24" down nozzle, 1-24" up nozzle. Click here to request more information
- 9,000 HP, Westinghouse model W-101M gas turbine only. 9,000 hp (6711 kw) @ approx. 6,000 rpm. Parts include complete set of new compressor blades. Axial compressor section; a complete set of compressor blades - refurbished (like new) - power turbine section. a DEMAG oxygen compressor also available. Click here to request more information
- 7500 HP General Electric Industrial Frame 3 single shaft gas turbine. Mdl 3001. Drive rated 7500 HP @ 6900 rpm, Nema conditions of 80 deg F and 1000' altitude w/zero duct losses. Unit is an indoor unit, burning natural gas. Has the following base mtd accessories starting turbine and clutch; dual lube oil cooler w/transfer valves; dual oil coolers w/transfer valves; accessory gear w/main gear driven lube oil pump; auxillary lube oil pump; emergency DC lube oil pump; gas fuel system including gas strainer mtd off base; inlet filter; inlet silencer; exhaust silencer. Unit can be converted to #2 distillate if required. Click here to request more information
- 3 MW AlliedSignal ASE 40 natural gas fired Gas Turbines, 50/60 Hz Turbine: Manufacturer MTU, Type ASE 40, Output 3 270 KW (ISO), Fuel Nat. Gas, Heat Rate 13.479 KJ/KWh, Exhaust Gas Temp./Qty. 603¦C / 12.69 kg/s, Year of Installation 1999
Total Hours / Starts 0 hrs. / 0 starts, Power Turbine Speed 15 400 1/min. Generator Manufacturer A.van Kaick, Voltage 10,5 kV, Frequency 50 Hz / 60Hz, Power Factor 0.8, Gas Generator Speed 19 291 1/min, Gearbox Cincinnati epicyclical gearbox type RTP 56 II flanged to the alternators flange. Package Design Sound atten Sound attending, common base frame with integrated lubrication oil tanks for gas turbine and gearbox. The weight of the module incl. the air system is approx. 30.000 kg. Warranty 12 month after commissioning. Optional Equipment available. Generator protection panel incl. All necessary protection relays for safe operation of the gernerator incl. Synchronizing Device for operation parallel to the grid. Motor control Centre (MCC) for all auciliary drives inc. UPS for lube oil pump and 24 VDC supply to control panel. Price "as/where is" FOB North Sea Port EUR 1.2 Mil / Each Conversion to 60 Hz Approx. EUR 100 000.- / Each - Subject to prior sale - The units are designed for either Simple Cycle Operation with the exhausted gas flowing directly to an optional stack or for Combined Heat and Power (CHP) Operation with use of the exhausted gas for direct process drying purposes or process steam generation in a Heat Reovery Steam Generator (HRSG). Dimensions Module Length Width Height Height g.t. module Height air system L B H H1 H2 [mm] [mm] [mm] [mm] [mm] ASE 40 7.020 2.500 6.350 3.150 3.200 The inlet and outlet air ducts external to the module can be adapted to site specific requirements. Technical data Altitude above sea level m 0, Ambient pressure (deducted) mbar 1013, Suction air temperature ¦C 15,0, Rel air humidity % 60, Inlet loss mbar 10, Exhaust loss mbar 20, Fuel pressure barg 15, Lower Heating Value kJ/kg 47795, Water Injection kg/h 0, Load % 100, Fuel input kW 11501, Fuel mass flow Kg/h 867, Electrical Efficiency % 26,71, Exhaust Specific heat kJ/kg K 1,1751, Exhaust gas composition, Water vapour Mol-% 7,56, CO 2 Mol-% 3,42, O2 13,38, N2 74,75, Argon 0,90, Nox rel to 15% =2, dry mg/nm3 147,60, CO rel to 15% =2, dry mg/nm3 35,63. Click here to request more information
- Gas Turbine AlliedSignal ASE 40
- 1.1 General Description: The AlliedSignal gas turbine type ASE 40 is a cold-end drive engine designed for stationary applications. The gas turbine incorporates innovative aerospace technologies which have been well proven with the other members of the AlliedSignal engine family. Over 20.000 AlliedSignal gas turbine have accomplished more than 70 million hours of world-wide operation, providing excellent reliability in demanding aerospace and industrial environments. The ASE 40 gas turbine has cold start ability allows it to reach maximum power within 45 seconds after starting. The Gas turbine when employed in stationary applications, is the basis of a very compact generating set making it the perfect solution for co-generation applications where the gas turbine module and heat recovery equipment need to be integrated in the limited space of existing plants (e.g. boiler houses).
- 1.2 Design features: The ASE 40 gas turbine comprises the following main components: inlet housing, accessory gearbox, gas producer module, combustor, power turbine. The gas turbines inlet housing forms the main supporting structure and has 4 pads for pedestal mounting. All other main components are supported by the inlet housing. Mounted to the underside of the inlet housing is the accessory gearbox which provides vertical power take-offs for auxiliaries and a connection for the starter motor. The gas producer module consists of the compressor with 7 axial and 1 centrifugal stages and is driven by a two-stage axial turbine. The accessory gear box is driven by the gas generator rotating group thorough bevel gears. The combustor is of the reverse flow annular chamber design utilising 28 fuel nozzles and providing compactness, high efficiency and low emissions. The hot end of the engine consists of a two-stage axial flow power turbine and related support housing. The power shaft runs coaxially through the compressor rotor to the front end of the gas turbine where the power take-off is located.
- Gearbox and Coupling shaft: Single epicyclic gear for flange mounting to the generator. Reduction of the power turbine speed down to 1500 rpm for 50 Hz applications. The power take-off of the turbine is connected to the gearbox via a high speed shaft with membrane type flexible coupling and crowned spline connection to the gear.
- Generator: Air-cooled, brushless, synchronous medium voltage alternator in accordance with IEC 34, equipped with two sleeve bearings, construction type B3, protection class IP 23, insulation class F, temperature rise acc. to class B. with the following features: bearing temperature monitoring equipment, external lube oil supply for the bearings (common with gear box lube oil system), winding temperature monitoring equipment, triple current transformers for measuring, protection and differential protection, electronic three function voltage regulator for parallel to the grid operation, anti-condensation heating,
- Generating set: The gas turbine and the alternator / gearbox unit are rigidly mounted and aligned on a common base plate.
- Exhaust system: Exhaust diffuser tailpipe in stainless steel, compensator and counter flange for connection to the external exhaust system (heat recovery unit, silencer or stack); The diffuser is connected to the soundproof enclosure with a flexible expansion joint.
- Fuel system: Pipework internal to the module including gas fuel regulating valve, shut-off valves and final filter. Flange connection to the customer gas supply system.
- Combustion air system: 2 stage air cleaner acc. to class EU4 and EU7 mounted in the upper part of the soundproof enclosure including anti-icing flap in the inlet air ducting, compensator between filter housing and inlet plenum and stainless steel inlet plenum designed for optimum air flow to the gas turbine compressor.
- Start system: Hydraulic starter motor mounted on the auxiliary gearbox of the gas turbine. The starter motor is driven an hydraulic oil system internal to the module with tank, electrical driven hydraulic oil pump, valves and piping.
- Lube oil system for gear box and alternator bearings: Lube oil system including immersion type pump, oil cooler (air/oil), oil filter, temperature control valve, pressure and level monitoring, air/oil separator and preheater, completely mounted in the module.
- Lube oil system for turbine: Lube oil system including tank, oil pumps, oil cooler (oil/oil), oil cleaner, pressure and level monitoring, completely mounted in the module.
- Compressor Washing System (Off-line): Wash water injectors mounted on the engine, flexible hose for connection to an mobile wash skid equipped with pump and tanks for wash solvent and water.
- Soundproof enclosure: Soundproof enclosure for noise attenuation to 85 dB (A) at 1m distance of the module, including maintenance access doors, Module cooling air ducting (inlet/outlet) incl. filter, fans, silencers and motor driven flaps, Air ducting for oil cooler incl. Fan, silencer and filter, Integrated combustion air cleaner housing (see also Chapter 7), Outlet air bypass duct for anti-icing, Noise attenuation to 75 dB (A) at 1m available on demand.
- Safety: The enclosure is equipped with an automatic fire protection and gas detection system, including CO2 fire extinguishing system with bottles, Fire detection system equipped with temperature and flame sensors, Gas detection system with gas sensors. The detection of gas or fire in the module automatically generates an immediate emergency shutdown, closing the external fuel shut-off valves.
- Controls and Auxiliaries: Control panel for installation near to the module equipped with PLC and local man / machine interface panel mounted display with the following functions: Monitoring of all relevant parameters of the engine and the module, generating alarms and shutdowns, Interfacing to the plant security chain (e.g. heat recovery system), Start and stop sequence of the engine, Control of all auxiliaries of scope of supply, Electronic speed- and output governor, Vibration monitoring on turbine and gearbox, Display of all values and parameters, Serial interface port for connection to a superior control system, Possibility for connection of a modern system for remote control,
- Documentation: Two sets of manuals in English language for the scope of supply is available.
- Testing and Acceptance: The main components are factory tested and provided with approval certificates by the suppliers.
- 2,460 HP Worthington gas expander turbine. Mdl 45BB6, Frame 4S, SN 25650, Shop Order #U-14673. 8016 rpm. Inlet 103.5 psia @ 1000 deg F, exhuast 14.9 psia. (4) rateau stages. CCW rotation from thrust end of expander. Casing steam end-chrome moly; exhaust end-cast steel. Includes gear reducer. Max pressure 125 psi, max flow 47600 lbs/hr. Click here to request more information
- REFURBISHED 2.0 MW natural gas turbinegenerator set. Type PGT 2 - Manufacturer Nuovo Pignone - Italy, Fuel Natural Gas, Year of Manufacturing 1996, Approx. Operating Hours/Starts 16.000/400, Next Revision due at 35 to 40.000 hrs., Alternator Voltage 6.000 V - 50 Hz, Transformer available 6.0/20 KV, Compressor inlet temperature 59¦F 15¦C, Compressor inlet pressure 14.7 PSIA 760 mm of Hg, Design output 2.000 KW, Efficiency 25 %, Design fuel consumption (LHV) 14400 KJ / kWh, Ratio HHV / LHV 1.1, Design exhaust flow 38.520 Kg / h, Design shaft 22.500 RPM Units complete with sound enclosure and control panels. Price "as is" ex works Euro 850 000.00. Technical Details see below. Click here to request more information
- The turbogenerator set has been refurbished to "zero hours" condition. The proposed unit was originally supplied by Nuovo Pignone and maintained exclusively by G.E. personnel. The turbogenerator reconditioned to "Zero Hours" will permit us to give you the same guarantee as per new unit (8000 firing hours or 18 months from date of shipment).
- 1.1 SCOPE OF SUPPLY This proposal includes the reconditioning to zero hours, design, manufacture, packing and Ex present site delivery of No. 1 Gas Turbine + AC Generator Unit suitable for outdoor installation on-shore site and consisting of the following major components.
- 1.1.1 GAS TURBINE DATA SHEET G.E. / Nuovo Pignone PGT2 gas turbine is an heavy duty single shaft machine designed for Power Generation application - Seismic and 4 radial vibration type detectors connected with the gas turbine monitoring and protection system - Brush less excitation type with the necessary equipment suitable for the excitation control - Ventilation fans on the generator shaft ends - M.V. section with Current and Potential transformers (CT's & PT's) for metering and protection and Surge arrestors and lightning protection - Neutral isolated to the ground
- 1.1.10 NEW MISCELLANEA - Foundation bolts and plates - Packing - Fire fighting mean bottles for the fire estinguishing system to be installed outside the package, adiacent to the unit - Control cables, interconnecting the gas turbine generating unit skids with relevant control panels (100 mt extimated) - Interconnecting piping between the Gas Turbine Generating Unit and its Auxiliary skids - Instruction manuals for maintenance and operation (four copies) - Compressor water washing trolley for crank operation - Antice system - Note
- The units will be completely renewed by replacement of the hot gas path and each part which it may need. The refurbished turbogenerator shall have the same guarantee as per a new unit (8000 firings hrs or 18 months from shipment).
- The above proposal does not include site activities. We can provide the necessary personnel according to your installation schedule upon request.
- 1,600 HP Worthington CS tailgas expander. Mdl 4U, SN 30450, Shop Order #U-18256. 4-stages. Gas inlet 104.7 psia @ 900 deg F, exhaust 15 psia, 10324 rpm. CCW rotation from governor end. Drives Clark centrifugal compressor. Click here to request more information
- 645 HP General Electric gas expander, Model 7TDRS125-R5. Gas inlet 130 psig @ 392 F, exhaust 0.5 psig. 6" inlet, 10" exhaust, CW rotation. Click here to request more information
|